Product name, model, specification table of endoscopic linear cutter

Table 1: The basic dimensions of the endoscope linear cutting stapler  Unit: mm

model Specification Length L3 tolerance
P-ED12- S 60 ±2.0
C 155
L 240

Table 2: Basic dimensions of cutting components:                 Unit: mm

Size model Specification L2 Tolerance L1 Tolerance
S R
P-CC- 30 167 200 ±2.0 29 ±2.0
45 183 216 45
60 199 235 61

Table 3: Basic dimensions of staples:                                      Unit: mm

Staple heightStaple color Number of columns White(W) Blue(B) Green(G) Gray(H) Brown(T) Purple(P) Black(N) Tolerance
From   the inside out first row 2.5mm 3.5mm 4.8mm 2.0mm 2.0mm 3.0mm 4.0mm ±0.2
the second list 2.5mm 3.5mm 4.8mm 2.0mm 2.5mm 3.5mm 4.5mm ±0.2
Third column 2.5mm 3.5mm 4.8mm 2.0mm 3.0mm 4.0mm 5.0mm ±0.2
/laparoscopicstapler-product/

II. Endoscopic linear cutter stapler performance:

The sleeve and body of the endoscope linear cutting stapler can withstand a pulling force of not less than 98N without breaking, and the occlusal mechanism (jaw) formed by the nail seat and the staple cartridge should have a bite force of not less than 30N; cutting stapler And the components should be able to be assembled and disassembled smoothly, and the moving parts should be able to be easily pushed without jamming or loosening. The cutting assembly should be firm after being installed in the cutting stapler. The staples should be stable when installed in the cutting assembly, and they should not fall off after being shaken. The push buttons of the endoscope linear cutting stapler and the cutting assembly should be pushed flexibly on both sides, and the use should be safe. The reset of the movable handle should be flexible enough to be quickly reset when the handle is released. The joint structure of the R-endoscope linear cutting stapler should be flexible and unobstructed. The angle of the left and right swing should not be less than 45 degrees, and the firing must not occur. Blocking, the retraction of the cutting head should be unobstructed, and the formation of the suture nail is not affected by the swing angle.

III. Main structure composition of endoscopic linear cutter stapler:

The disposable endoscope linear cutting stapler and the cutting component are composed of a cutting component and a cutting stapler. The cutting component is composed of a staple cartridge, an anastomotic nail, a staple seat, a cutting knife, a push piece outer tube, and a component protective cover. The cutting stapler It is composed of a transmission rod, a sleeve, a steering wrench, a steering handle, a firing button, a propulsion handle, a movable handle and a fixed handle.