Single use anoscope with light source’s usage introduction

Single use anoscope with light source’s usage introduction

Related Products

The use of anoscope with light

Should be the first rectal digital examination, and then the right hand hold the anus mirror and thumb against the core, the anus mirror tip should be coated with lubricant, with the left thumb, index finger will pull the right hip, show the anus, with the anus lens massage anal edge, so that the sphincter relax; Then slowly insert into the umbilical direction, after passing through the anal canal to the sacral fossa into the ampulla rectum. Remove the core, after removing the core should pay attention to whether there is blood stain and the nature of blood stain, if there is a secretion in the rectum, use tweezers to wipe the cotton ball, and then check in detail; Check the mucosal color, pay attention to the presence of ulcers, polyps, tumors and foreign bodies, and then slowly pull out the anus mirror, pay attention to internal hemorrhoids, anal papilla, anal recess or anal fistula mouth at the tooth line.

Notes on the use of anoscope with light

1. Wear gloves or finger covers on the right hand and apply lubricating fluid. First, conduct finger examination around the anus to check whether there are masses, tenderness, verrucous objects and external hemorrhoids around the anus.

2. Test the tightness of the anal sphincter muscle. Normally, only one finger can be extended and the anal ring can be contracted, and the anal and rectal ring can be touched behind the anal canal;

3. Check the rectal wall for tenderness, fluctuation, mass and stenosis, and determine the size, shape, position, hardness and activity when touching the mass;

4. The anterior wall of rectum is 4 ~ 5cm away from the anal edge. The prostate can be touched in men and the cervix can be touched in women.

5. According to the requirements, double diagnosis examination should be performed if necessary;

6. After pulling out the finger, observe the fingertip for blood or mucus.

/single-use-anoscope-with-light-source-product/

Treatment of anoscope with light bacterial contamination

The number of bacteria on the surface of the anoscope in standby state was observed. With the increase of the use frequency and the extension of the use time of disinfectant, the bacteriostatic effect of the anoscope was gradually weakened, and the pollution was also aggravated. The monitoring results showed that it was obvious on the 5th to 7th day. Glutaraldehyde has been widely used in the disinfection and sterilization of medical instruments due to its high efficiency and low toxicity. However, its disinfection effect is greatly affected by factors such as the acceptance nature, concentration and pH value. Therefore, it is necessary to observe the change of its bactericidal effect by using microbial monitoring method. The results showed that the use time of disinfectant should be determined according to the number of equipment and the frequency of use, and it should be replaced every 3-4 days, generally not more than 5 days, to ensure the disinfection effect of disinfectant.